solar.halowerk.com
Uses rated electrical power, food mass, start and target temperature, specific heat and an explicit efficiency range supplied by the caller. Optional vessel heat, evaporation and a caller-defined hold phase can be included. It contains no recipes, recipe text, food-specific cooking claims or hidden food database; the output separates the thermodynamic lower bound from the practical range and is no
- Category
- Crypto & DeFi
- Starting price
- $0.002
- Paid calls · 30 days
- 12
- Unique payers · 30 days
- 12
Paid endpoints
6 endpoints, sorted by usage. Prices are per request.
- POST/low-wattage-cooking
Uses rated electrical power, food mass, start and target temperature, specific heat and an explicit efficiency range supplied by the caller. Optional vessel heat, evaporation and a caller-defined hold phase can be included. It contains no recipes, recipe text, food-specific cooking claims or hidden food database; the output separates the thermodynamic lower bound from the practical range and is no
$0.003Base3calls / 30d - POST/building-heat-demand
Computes a transparent planning estimate for space-heating demand. The method is not DIN, VDI, GEG or PHPP and must not be used as regulatory proof. It combines transmission heat loss from each envelope component, ventilation heat loss from heated volume and air changes, monthly heating degree days from the nearest DWD 1991-2020 temperature-normal station, stated internal gains and optional domest
$0.004Base2calls / 30d - POST/inverter-load-check
Continuous load is the sum of the running watts of all appliances marked as simultaneous. The surge check adds the largest single starting surge on top of the continuous load, which is the case that trips an inverter; simultaneous starts of two motors are reported separately as a second figure. Starting factors and power factors are design rules of thumb per appliance class and are stated in the r
$0.002Base2calls / 30d - POST/battery-cycle
Integrates the supplied current over time by the trapezoidal rule, so the result is only as good as the sampling interval; gaps longer than the stated max_gap_seconds are excluded and reported. Sign convention: positive current is charging, negative is discharging. Internal resistance is estimated from the largest current step in the series and is a rough figure, not a measurement under defined co
$0.004Base2calls / 30d - POST/autonomy-forecast
Daily energy balance and straight run-down from the figures supplied. Solar input is caller data in watt-hours per day; nothing is fetched and no weather is assumed. Time to empty means time to the reserve floor, not to zero. Idle draw and conversion efficiency apply to AC loads only. Ageing, temperature and Peukert behaviour are not modelled, which matters for lead acid far more than for LiFePO4.
$0.003Base2calls / 30d - POST/off-grid-weather-alarm
Uses the nearest current DWD MOSMIX_L station forecast, or a station explicitly supplied by the caller. Global irradiance drives a transparent PV estimate and forecast wind speed drives a stated generic turbine curve; neither replaces a site-specific yield model. A constant hourly load and optional battery are simulated over 12 to 120 hours. The result is an installation-risk signal, not an offici
$0.005Base1calls / 30d